Two of most accurate and commonly used temperature sensors are RTD & Thermocouple.Thermowells are tubular fittings used to protect temperature sensors installed in industrial processes. 

 - - - - - - - - - +
X
010
Model
 
 
 Product descriptionProd. time (days)
Temperature Sensor0
X
020
Head Material
 
 
  Prod. time (days)
Aluminum0
Stainless Steel 3160
Without Head0
X
030
Connection Head
 
 
  Conduit threadProcess ThreadProd. time (days)
No Additional Enclosure0
Universal Connection Head with 1 Elec. Entry/IP65 M20 x 1.5M20 x 1.50
Explosion Proof Connection Head with 1 Elec. Entries/IP67 M20 x 1.5M20 x 1.50
Remote HeadM20 x 1.5M20 x 1.50
X
040
Sensor lead wire termination
 
 
  DetailsProd. time (days)
Flying Lead No Springs on DIN plate0
Terminal BlockWith Spring on DIN 437620
Spring loaded No Plate with spring loaded Process Connection Adaptor0
X
050
Sensor type
 
 
  Prod. time (days)
RTD, PT-100, Single Element, 2 Wires, Thin Film, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)0
RTD, PT-100, Single Element, 3 Wires, Thin Film, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)0
RTD, PT-100, Single Element, 4 Wires, Thin Film, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)0
RTD, PT-100, Dual Element, 2 Wires, Thin Film, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)0
RTD, PT-100, Dual Element, 3 Wires, Thin Film, 4 Wires Termination Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)0
RTD, PT-100, Single Element, 2 Wires, Wire Wound, Class AA (-50..250 °C), Class A (-100..450 °C), Class B (-196..600°C)0
RTD, PT-100, Single Element, 3 Wires, Wire Wound, Class AA (-50..250 °C), Class A (-100..450 °C), Class B (-196..600°C)0
RTD, PT-100, Single Element, 4 Wires, Wire Wound, Class AA (-50..250 °C), Class A (-100..450 °C), Class B (-196..600°C)0
RTD, PT-100, Dual Element, 3 Wires, Thin Film, 6 wires Termination, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)0
Thermocouple , Type E Single Element, Ungrounded, Class 1, -40 to 800 °C0
Thermocouple, Type E Dual Element, Isolated, Ungrounded, Class 1, -40 to 800 °C0
Thermocouple, Type K, Single Element, Ungrounded, Class 1, -40 to 1000 °C0
Thermocouple, Type K Dual Element, Isolated, Ungrounded, Class 1, -40 to 1000 °C0
Thermocouple, Type J, Single Element, Ungrounded, Class 1, -40 to 750 °C0
Thermocouple, Type J Dual Element, Isolated, Ungrounded, Class 1, -40 to 750 °C0
Thermocouple, Type T, Single Element, Ungrounded, Class 1, -40 to 350 °C0
Thermocouple, Type T Dual Element, Isolated, Ungrounded, Class 1, -40 to 350 °C0
Thermocouple, Type N Single Element, Isolated, Ungrounded, Class 1, -40 to 350 °C0
Thermocouple, Type N Dual Element, Isolated, Ungrounded, Class 1, -40 to 350 °C0
Thermocouple, Type R, Single Element, Ungrounded, Class 1, 0 to 1000 °C0
Thermocouple, Type R Dual Element, Isolated, Ungrounded, Class 1, 0 to 1000 °C0
Thermocouple, Type S, Single Element, Ungrounded, Class 1, 0 to 1000 °C0
Thermocouple, Type S Dual Element, Isolated, Ungrounded, Class 1, 0 to 1000 °C0
Special Item0
X
060
Sensor Diameter
 
 
  Prod. time (days)
3 mm0
5 mm0
6 mm0
6.3 mm0
8 mm0
10 mm0
0
X
070
Dimension Unit
 
 
  DetailsProd. time (days)
Metric units (mm)Only applies to lengths0
English/U.S. units (inches)0
X
080
Sensor immersion Length
 
 
   DetailsProd. time (days)
xxxx mm50 to 2000 mm in 5-mm increments (when ordered with Dimension units code M)Example of a 50 mm length: 00500
xxx.x inches2 to 80 inches in ¼ inches increments (when ordered with Dimension units code E)Example of a 6.25-in. length where the second decimal is dropped off: 00620
X
090
Process Connection
 
 
  Prod. time (days)
No Additional Fitting (The selected connection head will determine process connection)0
½-14 NPT Male0
G ½ (BSPP) Male0
¼-18 NPT Male0
G ¼ (BSPP) Male0
1/8-27 NPT Male0
G 1/8 (BSPP) Male0
Other0
X
100
Extensions
 
 
  DetailsProd. time (days)
No Coupling, Nipple and Union 0
Coupling Adaptor, length: yyy mmyyy refers to the Length of Coupling Extension must be greater than 65mm0
Coupling Nipple-Union Adaptor, length: yyy mmyyy refers to the Length of Coupling Extension must be greater than 83mm0
One Nipple, length: xxx mmxxx refers to the length of Nipple. e.g. Y050-N000 means one nipple with 50mm length.0
X
110
More Options
 
 
  Prod. time (days)
Wire color per ISA0
Wire color per IEC0
Assemble sensor to specific temperature transmitter (PVC Tube for Sensor Protection)0
External ground screw0
Plug & Chain0
SST tag Plate, Includes Serial No., Customer Tag No. & Sensor Calibration Range Dimension: 3.5 x 6 Cm, Thickness 1 mm0
Compress Fitting Adjustable0
ATEX II 2G Exd IIC T6 Gb Explosion Proof0